white Westinghouse Airconditioner error codes

White Westinghouse Air Conditioner Error Codes

White Westinghouse Air Conditioner Error Codes and Solutions

Error Code Description Solution
E1 Indoor temperature sensor error. Check the indoor temperature sensor connection. Replace it if it is malfunctioning.
E2 Outdoor temperature sensor error. Inspect the outdoor temperature sensor and its connections. Replace if necessary.
E3 Communication error between indoor and outdoor units. Ensure the wiring between the indoor and outdoor units is secure and undamaged. Check the control board if issues persist.
E4 High-pressure protection. Check for blockages in the refrigerant lines or compressor issues. Ensure proper airflow around the unit.
E5 Low-pressure protection. Inspect the refrigerant level and check for leaks in the system. Recharge refrigerant if necessary.
E6 Refrigerant leakage detected. Contact a technician to locate and repair any leaks, then recharge the refrigerant.
E7 Evaporator temperature sensor error. Check the evaporator temperature sensor for functionality. Replace it if it’s faulty.
E8 Compressor overload. Ensure there are no blockages affecting airflow. Consult a technician if the error continues.
E9 Drain overflow. Inspect the drain pan and line for blockages. Clear any debris to allow proper drainage.
E10 System protection mode activated. Allow the unit to cool down and reset.
E11 Inverter communication error. Check communication wires between the inverter and control board. Ensure all connections are secure.
E12 Indoor fan motor malfunction. Inspect the indoor fan motor for operation. Replace if it’s not working correctly.
E13 Outdoor fan motor malfunction. Check the outdoor fan motor. If it’s not operating, repair or replace as needed.
E14 Ambient temperature sensor error. Inspect the ambient temperature sensor and ensure it is connected properly. Replace if faulty.
E15 High discharge temperature. Check for refrigerant overcharge or airflow issues. Resolve any blockages in the system.
E16 Low discharge temperature. Inspect the system for undercharge issues or compressor problems and recharge if needed.
E17 System overload protection triggered. Allow the unit to cool down and check for any obstructions affecting airflow.
E18 Defrosting failure. Check the defrost sensor and heater. Ensure they are functioning correctly, and replace them if necessary.
E19 Power supply error. Inspect the power supply for stability and proper voltage. Ensure all electrical connections are secure.
E20 Control board malfunction. Check for visible damage on the control board and consider replacing it if necessary.
E21 Unit not responding to remote control. Ensure the remote control batteries are functional. Check for obstacles blocking the signal.
E22 Air flow obstruction detected. Inspect air filters and clear any debris around the unit.
E23 Compressor communication error. Check the wiring and connections between the compressor and control board. Replace any damaged wires.
E24 Low refrigerant warning. Inspect for refrigerant leaks and recharge the system if necessary.
E25 High refrigerant temperature. Check for refrigerant overcharge or compressor issues. Ensure condenser coils are clean.