Vestar Airconditioner Error Codes
Error Code | Description | Solutions |
---|---|---|
E1 | Room Temperature Sensor Error | Indoor air sensor faulty or disconnected from PCB |
E2 | Outdoor Coil Sensor Error | Check outdoor unit condenser coil sensor fault or disconnected from outdoor PCB |
E3 | Indoor Coil Sensor Error | Check outdoor unit condenser coil sensor fault or disconnected from indoor PCB |
E4 | Fan Motor Error Indoor | Check indoor fan motor working, check restrictions, check feedback |
E5 or 5E | Communication Error | Check indoor and outdoor wiring connections fault |
F1 | IPM Fault | Check outdoor PCB IPM, replace outdoor PCB |
F2 | PFC Error | Check outdoor unit PCB power supply circuit fault |
F3 | Compressor Operation Error | Check valves and gas choke, check pipeline blocked, replace compressor if above is clear |
F4 | Exhaust Sensor Error | Check outdoor discharge temperature sensor or outdoor condenser sensor |
F5 | Compressor Protection | Check compressor terminal and OLP if available. Replace compressor if OLP is clear |
F6 | Outdoor Ambient Temperature Error | Check outdoor air sensor faulty or disconnected from PCB |
F7 | Power Supply Error | Check loose connections of input power supply, check low voltage or high voltage |
F8 | Outdoor Module Comm Error | Check outdoor unit wiring between main and sub PCB |
F9 | EPROM Error | Check outdoor unit 8 pin EPROM, replace EPROM |
F0 | Fan Motor Error | Check outdoor unit fan motor winding and circuit, replace motor if supply is clear |
FA | Suction Temp Error | Check four-way valves operation, check suction temp sensor |
FB | Fan Motor Error | Check feedback of indoor fan motor. Replace motor if feedback not clear |
P4 | Outside Dish Error | Refrigerant checks |
P5 | Exhaust Protection | Check related components |
P6 | Indoor Heat Protection | Check related parts |
P7 | Indoor Antifreeze Protection | Check related components |
P8 | Outdoor Over Current Protection | Check related components |
All brands appliances and airconditioner error codes
Link: https://mbmtech.in/appliances-error-codes/
Airconditioner Parts and Components Testing
Link: https://mbmtech.in/airconditioner-components-and-parts-testing/
Vestar Air Conditioner Repair, Installation, and Gas Refilling FAQ
General Questions
-
Does MBM TECH Nashik provide services for Vestar air conditioners?
Yes, MBM TECH Nashik specializes in repair, installation, and gas refilling services for Vestar air conditioners. -
What types of Vestar air conditioners do you service?
We provide services for all types of Vestar air conditioners, including:- Split AC
- Window AC
- Inverter AC
-
Do you offer services for both residential and commercial air conditioners?
Yes, MBM TECH Nashik caters to both residential and commercial Vestar air conditioner needs.
Repair Services
-
What are common issues with Vestar air conditioners that you repair?
We handle a variety of issues, including:- AC not cooling properly
- Unusual noises during operation
- Water leakage
- Faulty thermostat
- Electrical or wiring issues
-
How can I know if my AC needs repair?
Signs that your Vestar AC might need repair include:- Insufficient cooling
- Increased energy bills
- Foul odors from the unit
- Unusual sounds like grinding or hissing
-
Can MBM TECH Nashik repair older models of Vestar air conditioners?
Yes, we can repair both older and newer models of Vestar air conditioners, as long as the parts are available.
Installation Services
-
Do you provide installation services for new Vestar air conditioners?
Yes, we offer professional installation services for all Vestar AC units. -
What is included in your installation service?
Our installation service includes:- Mounting and securing both the indoor and outdoor units
- Connecting electrical components and refrigerant lines
- Testing the unit for proper operation
-
How long does it take to install a Vestar AC?
The installation process typically takes around 3 to 5 hours, depending on the type and location of the AC unit.
Gas Refilling Services
-
When does an AC require gas refilling?
Gas refilling may be necessary if:- The AC isn’t cooling properly
- There’s a refrigerant leak
- The system runs continuously without reaching the desired temperature
-
What type of refrigerant is used in Vestar AC gas refilling?
We use the specific refrigerant recommended for your Vestar AC model, including R22, R410A, or R32. -
How do you ensure no leaks after gas refilling?
Our technicians conduct a thorough inspection and pressure test to make sure there are no refrigerant leaks.
Customer Support
-
How can I book a service with MBM TECH Nashik?
You can book a service by visiting our contact page or by calling our customer care number. -
Do you offer same-day service?
Yes, we offer same-day service for most repair and gas refilling requests, depending on technician availability. -
Is there a warranty on your services?
We provide a service warranty for both repairs and installations. For more details, feel free to contact us directly.
If you need expert help with Vestar air conditioner repair, installation, or gas refilling in Nashik, don’t hesitate to contact MBM TECH Nashik for fast and reliable service.