whirpool refrigerator error code

whirpool refrigerator error

Whirlpool Refrigerator Error Codes
Error Code Description Repair Method
E1 Fridge Temperature Sensor Error Check the fridge sensor and replace if it’s faulty.
E2 Freezer Temperature Sensor Error Inspect the freezer sensor for damage and replace as needed.
E3 Defrost Sensor Error Test the defrost sensor and wiring; replace if defective.
E4 Compressor Error Ensure proper ventilation; check compressor operation and replace if necessary.
E5 Fan Error Inspect the evaporator and condenser fans for obstructions; replace if faulty.
E6 Door Open Error Check the door switch for functionality and replace if needed.
E7 Power Failure Error Check the power supply and reset the refrigerator if necessary.
E8 Ice Maker Error Inspect the ice maker for blockages or mechanical issues; replace if needed.
E9 Water Filter Error Replace the water filter or ensure proper installation.
E10 Communication Error Check wiring connections between the control board and sensors; reset if needed.
Whirlpool Refrigerator Error Troubleshooting

Whirlpool Side-by-Side Refrigerator Error Troubleshooting

Error Code Description Solutions
E0 Cooling loss or Open Door Check fan motor, gas leakage, gas choke, or door open for longer than 10 minutes.
E1 Refrigerator Temperature Sensor error Check wiring of temperature sensor to main PCB and sensor in refrigerator compartment. Test with multimeter on resistance range; value should be between 1.5k to 3k ohm at 30°C.
E2 Freezer Sensor error Check wiring of temperature sensor to main PCB and sensor in freezer compartment. Test with multimeter on resistance range; value should be between 1.5k to 3k ohm at 30°C.
E3 or F3 Defrost Sensor error Check wiring of temperature sensor to main PCB and evaporator defrost sensor in freezer compartment. Test with multimeter on resistance range; value should be between 1.5k to 3k ohm at 30°C.
E4 Fridge Defrost Sensor Check wiring of temperature sensor to main PCB and evaporator defrost sensor in refrigerator compartment. Test with multimeter on resistance range; value should be between 1.5k to 3k ohm at 30°C.
E5 Freezer Defrost Sensor Error Check wiring of temperature sensor to main PCB and evaporator defrost sensor in freezer compartment. Test with multimeter on resistance range; value should be between 1.5k to 3k ohm at 30°C.
E6 Communication Error Check wiring of main PCB to display PCB.
E7 Exit Sensor error Check ambient sensor, wiring of temperature sensor to main PCB, and evaporator defrost sensor in freezer compartment. Test with multimeter on resistance range; value should be between 1.5k to 3k ohm at 30°C.
E8 Sealed System Error This is likely related to the compressor, refrigerant levels, or other cooling components.
E9 Freezer High Temperature Error The freezer door may have been left open for longer than 3 minutes.
PC Pantry Room Temperature Sensor Error Check pantry sensor, wiring of temperature sensor to main PCB, and sensor in pantry compartment. Test with multimeter on resistance range; value should be between 1.5k to 3k ohm at 30°C.
SY or CE Communication Error Check wiring from main PCB to display PCB. Replace PCBs one by one to test.
rd Defrost Error Check heater, thermal fuse, wiring between main PCB and heater, and bimetal if present.
DF Fan Motor Error Check fan motor externally and verify wiring.