Error Code |
Description |
Solution |
1C or 1E |
Freezer duct sensor |
Open the freezer duct in freezer compartment and check the sensor fixed in the duct or other location except evaporator coil that is called freezer sensor. Check it on multimeter set on 20..K range, if it shows 0 or 1 then replace it. If it shows 4K to 6K at normal room temperature then check its wiring and connectors if it is broken or gone rusty. If wiring and connectors are okay, then replace the main PCB. |
2C or 2E blinking error |
Fridge sensor error |
Open the fridge duct in the fridge/ref compartment and check the sensor fixed in the duct or other location except evaporator coil that is called ref sensor. Check it on multimeter set on 20..K range, if it shows 0 or 1 then replace it. If it shows 4K to 6K at normal room temperature then check its wiring and connectors if it is broken or gone rusty. If wiring and connectors are okay, then replace the main PCB. |
4C or 4E blinking error |
Freezer defrost sensor |
Open the freezer duct in the freezer compartment and check the sensor connected on the evaporator coil. That is called the freezer defrost sensor and it has been either short or open. Check the ohm value of the sensor with a multimeter set on 20..K range, if it shows 0 or 1 then replace it. If it shows 4K to 6K at normal room temperature then check its wiring and connectors if it is broken or gone rusty. If wiring and connectors are okay, then replace the main PCB. |
6C or 6E blinking error |
Room ambient sensor error |
Open the panel of the main PCB and check if any sensor is available nearby or open the upper hinges cover and check if a sensor is available there. That is the ambient sensor. Remove and check on the multimeter. Check the ohm value of the sensor with a multimeter set on 20..K range, if it shows 0 or 1 then replace it. If it shows 4K to 6K at normal room temperature then check its wiring and connectors if it is broken or gone rusty. If wiring and connectors are okay, then replace the main PCB. |
8C or 8E blinking error |
Ice maker sensor |
Open the freezer and check a sensor available connected to the ice maker unit. Remove and check on the multimeter. Check the ohm value of the sensor with a multimeter set on 20..K range, if it shows 0 or 1 then replace it. If it shows 4K to 6K at normal room temperature then check its wiring and connectors if it is broken or gone rusty. If wiring and connectors are okay, then replace the main PCB. |
13C or 13E blinking error |
Humidity sensor |
Open the fridge/ref compartment and remove the duct. Open the fridge duct in the fridge/ref compartment and check the sensor fixed in the duct or other location except the evaporator coil that is called the humidity sensor. Check it on multimeter set on 20..K range, if it shows 0 or 1 then replace it. If it shows 4K to 6K at normal room temperature then check its wiring and connectors if it is broken or gone rusty. If wiring and connectors are okay, then replace the main PCB. |
21C or 21E blinking error |
Freezer fan motor |
Open the freezer duct and check if the freezer fan is jammed or blocked or if connectors have gone rusty. Check the fan motor on a 12VDC supply externally. If not working, then replace the fan motor. |
23C or 23E blinking error |
C fan error |
Fan near the compressor is not working. Fan is jammed or blocked or connectors have gone rusty. Check the fan motor on a 12VDC supply externally. If not working, then replace the fan motor. |
24C or 24E blinking error |
Defrosting error |
Check the heater, thermal fuse, and defrost sensor. |
26C or 26E blinking error |
Icemaker error |
Check if water is supplied properly in the icemaker by pushing the test switch given below the icemaker unit. If not working, then replace the icemaker unit. |
27C or 27E blinking error |
Damper heater error |
Check the connection of the damper. If it is proper, then replace the damper. |
41C or 41E blinking error |
Communication error |
Error is seen if the display and main PCB connection are broken. Check wiring continuity and connectors. If these are okay, then replace the display and/or main PCB both. |
44C or 44E blinking error |
Communication between main PCB and inverter PCB |
Check wiring and connectors. If found okay, then replace both PCBs. |
C71 or E71 |
Freezer sensor sense rise in temperature in freezer compartment |
Reason may be freezer defrost cycle not working, freezer door was opened for a long time, gas-related issues. |
C72 or E72 |
Fridge section abnormal temperature |
Check as C71 given above. |
C81 or E81 |
Compressor starting issues |
Reason 1 – Gas choke, 2 – Condenser fan not working, 3 – Compressor locked, 4 – Inverter PCB fault, 5 – Input power supply. |
C82 or E82 |
Inverter PCB fault |
Replace the inverter PCB. |
C83 or E83 |
Compressor wiring issues |
Check and replace the compressor wiring. |
C84 or E84 |
Compressor locked |
Replace the compressor. |
C85 or E85 |
Low voltage input supply |
Check voltage and replace the inverter PCB if required. |
C86 or E86 |
Over voltage |
Check the input power supply voltage. It should be under 250 VAC. |
No display model refrigerator has LED light on main pcb which indicate error codes as they blinking if any parts failure occurs
Error Code |
Description |
C01 | Freezer Sensor |
C02 | Refrigerator Sensor error |
C03 | Bottom room Sensor error |
C04 | Freezer Defrost Sensor |
C05 | Refrigerator Defrost Sensor |
C06 | Outdoor temperature Sensor |
C07 | Pantry room Sensor |
C08 | Ice maker sensor error |
C09 | Cool select zone sensor error |
C10 | Curd maker sensor error |
C11 | Cool select zone Defrost Sensor |
C13 | Humidity sensor error |
C14 | Refrigerator ice maker sensor error |
C15 | Refrigerator ice making room Sensor error |
C16 | Refrigerator Humidity sensor error |
C17 | Carbonated water temperature sensor error |
C18 | Freezer room rotary switch error |
C19 | Refrigerator room rotary sensor error |
C20 | Crystal ice maker sensor error |
C21 | Freezer fan motor error |
C22 | Refrigerator fan motor error |
C23 | Condenser fan motor error |
C24 | Freezer Defrost error |
C25 | Refrigerator Defrost error |
C26 | Freezer ice maker faulty |
C27 | Damper Heater error |
C28 | Deodorizer fan motor error |
C29 | Cool select zone Defrost error |
C30 | Top room abnormal high |
C31 | Cool select zone indoor fan motor error |
C32 | Bottom room abnormal high |
C33 | Freezer ice pipe heater error |
C34 | Water tank heater error |
C35 | Freezer Defrost early return error (Low resistance) |
C36 | Refrigerator Defrost early return |
C37 | Cool select zone early return |
C38 | Curd fan motor error |
C39 | Refrigerator ice maker functioning error |
C40 | Ice making room Sensor error |
C41 | Communication Error main PCB and Display PCB |
Error Code |
Description |
C44 | Communication Error, main PCB to F COMP |
C45 | Communication Error, main to R Comp |
C46 | Input/output expander Communication error |
C47 | Communication Error, main to dispenser |
C48 | Easy open 1 door Communication error |
C49 | Easy open door 2 Communication error |
C50 | Easy open Door 3 Communication error |
C51 | Easy open door 4 Communication error |
C52 | WiFi Communication error |
C53 | Inverter AI streaming Communication error |
C54 | Inverter background OTN Communication error |
C56 | Lighting sensor error |
C57 | Wine Refrigerator Bottom room Humidity sensor error |
C58 | Wine Refrigerator middle room Humidity sensor error |
C59 | Pantry 2 room Sensor error |
C61 | Refrigerator ice duct heater error |
C62 | Cool select zone fan motor error |
C63 | Sub damper heater error |
C64 | Refrigerator ice pipe heater error |
C65 | Refrigerator ice bucket heater error |
C66 | Door handle heater error |
C67 | Easy open door 1 function error |
C68 | Easy open door 2 function error |
C69 | Easy open door 3 function error |
C70 | Easy open door 4 error |
C71 | Freezer abnormal high temperature error |
C72 | Refrigerator abnormal high temperature error |
C73 | Cool select zone abnormal high temperature error |
C74 | Transparent ice maker functioning error |
C75 | Transparent ice maker ice pipe heater error |
C76 | Auto fill overflow error |
C77 | Camera initial error |
C78 | Cabinet rear heater error |
C79 | Showcase heater error |
C80 | Pantry fan 2 error |
C81 | Freezer compressor operation error |
C82 | Freezer compressor IPM fault |
C83 | Freezer compressor location detect error |
C84 | Freezer compressor rotor locked error |
C85 | Freezer compressor low voltage error |
C86 | Freezer compressor over voltage error |
C87 | Refrigerator compressor operation error |
C88 | Refrigerator compressor IPM fault |
C89 | Refrigerator compressor location detect error |
C90 | Refrigerator compressor motor locked error |
C91 | Refrigerator compressor low voltage error |
C92 | Refrigerator compressor over voltage error |
C93 | Carbonated water overflow error |
C94 | Carbonated water supply error |
C95 | Gas input motor operation error |
C96 | Compressor IPM shutdowns error |
C97 | R compressor IPM shutdown error |
C98 | Left DOC motor operation error |
C99 | Right DOC motor functioning error |
Very fantastic info can be found on weblog.Raise your business