Error Code |
Description |
C01 | Freezer Sensor |
C02 | Refrigerator Sensor error |
C03 | Bottom room Sensor error |
C04 | Freezer Defrost Sensor |
C05 | Refrigerator Defrost Sensor |
C06 | Outdoor temperature Sensor |
C07 | Pantry room Sensor |
C08 | Ice maker sensor error |
C09 | Cool select zone sensor error |
C10 | Curd maker sensor error |
C11 | Cool select zone Defrost Sensor |
C13 | Humidity sensor error |
C14 | Refrigerator ice maker sensor error |
C15 | Refrigerator ice making room Sensor error |
C16 | Refrigerator Humidity sensor error |
C17 | Carbonated water temperature sensor error |
C18 | Freezer room rotary switch error |
C19 | Refrigerator room rotary sensor error |
C20 | Crystal ice maker sensor error |
C21 | Freezer fan motor error |
C22 | Refrigerator fan motor error |
C23 | Condenser fan motor error |
C24 | Freezer Defrost error |
C25 | Refrigerator Defrost error |
C26 | Freezer ice maker faulty |
C27 | Damper Heater error |
C28 | Deodorizer fan motor error |
C29 | Cool select zone Defrost error |
C30 | Top room abnormal high |
C31 | Cool select zone indoor fan motor error |
C32 | Bottom room abnormal high |
C33 | Freezer ice pipe heater error |
C34 | Water tank heater error |
C35 | Freezer Defrost early return error (Low resistance) |
C36 | Refrigerator Defrost early return |
C37 | Cool select zone early return |
C38 | Curd fan motor error |
C39 | Refrigerator ice maker functioning error |
C40 | Ice making room Sensor error |
C41 | Communication Error main PCB and Display PCB |
C44 | Communication Error, main PCB to F COMP |
C45 | Communication Error, main to R Comp |
C46 | Input/output expander Communication error |
C47 | Communication Error, main to dispenser |
C48 | Easy open 1 door Communication error |
C49 | Easy open door 2 Communication error |
C50 | Easy open Door 3 Communication error |
C51 | Easy open door 4 Communication error |
C52 | WiFi Communication error |
C53 | Inverter AI streaming Communication error |
C54 | Inverter background OTN Communication error |
C56 | Lighting sensor error |
C57 | Wine Refrigerator Bottom room Humidity sensor error |
C58 | Wine Refrigerator middle room Humidity sensor error |
C59 | Pantry 2 room Sensor error |
C61 | Refrigerator ice duct heater error |
C62 | Cool select zone fan motor error |
C63 | Sub damper heater error |
C64 | Refrigerator ice pipe heater error |
C65 | Refrigerator ice bucket heater error |
C66 | Door handle heater error |
C67 | Easy open door 1 function error |
C68 | Easy open door 2 function error |
C69 | Easy open door 3 function error |
C70 | Easy open door 4 error |
C71 | Freezer abnormal high temperature error |
C72 | Refrigerator abnormal high temperature error |
C73 | Cool select zone abnormal high temperature error |
C74 | Transparent ice maker functioning error |
C75 | Transparent ice maker ice pipe heater error |
C76 | Auto fill overflow error |
C77 | Camera initial error |
C78 | Cabinet rear heater error |
C79 | Showcase heater error |
C80 | Pantry fan 2 error |
C81 | Freezer compressor operation error |
C82 | Freezer compressor IPM fault |
C83 | Freezer compressor location detect error |
C84 | Freezer compressor rotor locked error |
C85 | Refrigerator compressor operation error |
C86 | Refrigerator compressor IPM fault |
C87 | Refrigerator compressor location detection error |
C88 | Refrigerator compressor rotor locked error |
C89 | Freezer compressor IPM OLP error |
C90 | Freezer compressor OLP error |
Error Times |
Description |
Solution |
1 time |
Freezer duct sensor error |
Check and replace the freezer duct sensor if needed. |
2 times |
Freezer Defrost Sensor |
Inspect the defrost sensor for any faults; replace if necessary. |
3 times |
RT sensor |
Test the RT sensor for continuity and replace if defective. |
4 times |
Freezer knob error |
Ensure the freezer knob is correctly installed and functioning. |
5 times |
Freezer Defrosting error |
Check the defrost heater and thermal fuse; replace if needed. |
6 times |
Refrigerator duct sensor |
Verify the sensor’s connection and replace if not functioning. |
7 times |
Ref defrost sensor |
Check the defrost sensor for any malfunctions and replace it. |
9 times |
Ref knob rotary error |
Inspect the rotary knob mechanism for issues and repair or replace. |
10 times |
Compressor error and/or PCB error |
Test the compressor and PCB connections; repair or replace as needed. |
11 times |
Freezer fan motor |
Check the freezer fan motor for functionality; replace if defective. |
12 times |
Ref fan motor |
Ensure the refrigerator fan motor is operational; replace if faulty. |
Error Code |
Error Description |
Solution |
1C ――― |
Freezer defrost error |
Check thermal fuse, defrost heater, bimetal, wiring connection slipped out. |
2C ――― |
Exit sensor or ambient sensor error |
Check resistance value of sensor (5K at 30°C), or connectors slipped out. |
3C ――― |
Refrigerator sensor error |
Check resistance value of sensor (5K at 30°C), or connectors slipped out. |
5C ――― |
Freezer defrost sensor error |
Check resistance value of sensor (5K at 30°C), or connectors slipped out. |
7C ――― |
Freezer fan motor error |
Check fan motor externally (12VDC); if fan works, check wiring feedback at PCB. |
Power Cool symbol ――― |
Compressor error |
Check resistance of compressor, check wiring continuity of UVW wires; if both are okay, replace compressor. |
Ice ON/OFF ――― |
Icemaker sensor error |
Check sensor below icemaker tray; check resistance value of sensor (5K at 30°C), or connectors slipped out. |
Error Code |
Description |
Solution |
1E |
Freezer Sensor |
Open freezer room duct and locate sensor in room. Value should be between 4k to 6k ohm at 30⁰C. Check if connectors may have slipped away. |
2E |
Fridge Sensor |
Open fridge room duct and locate sensor in room. Value should be between 4k to 6k ohm at 30⁰C. Check if connectors may have slipped away. |
4E |
Defrost Sensor (Freezer) |
Open freezer room duct and locate sensor on evaporator coil. Value should be between 4k to 6k ohm at 30⁰C. Check if connectors may have slipped away. |
5E |
Defrost Sensor (Fridge) |
Open fridge room duct and locate sensor on evaporator. Value should be between 4k to 6k ohm at 30⁰C. Check if connectors may have slipped away. |
6E |
Room Ambient Sensor |
Find ambient sensor near upper door hinge or in PCB control box. Value should be between 4k to 6k ohm at 30⁰C. Check if connectors may have slipped away. |
9E |
Cool Select Zone Sensor |
Open cool select zone and locate sensor. Value should be between 4k to 6k ohm at 30⁰C. Check if connectors may have slipped away. |
11E |
Cool Select Zone Defrost Sensor |
Open cool select zone and locate sensor on evaporator. Value should be between 4k to 6k ohm at 30⁰C. Check if connectors may have slipped away. |
13E |
Humidity Sensor |
Value should be between 4k to 6k ohm at 30⁰C. Check if connectors may have slipped away. |
14E |
Ice Maker Sensor (Fridge) |
Open fridge room, find ice maker kit, and locate sensor below ice tray. Value should be between 4k to 6k ohm at 30⁰C. Check if connectors may have slipped away. |
15E |
Ice Maker Sensor (Freezer) |
Open freezer room, find ice maker kit, and locate sensor below ice tray. Value should be between 4k to 6k ohm at 30⁰C. Check if connectors may have slipped away. |
16E |
Fridge Humidity Sensor |
Open fridge room and locate humidity sensor. Value should be between 4k to 6k ohm at 30⁰C. Check if connectors may have slipped away. |
21E |
Fan Motor (Freezer) |
Open freezer room duct and check if fan motor is jammed or stuck in ice. Reconnect and try again. Operate test mode to check if fan motor is working. Check wiring, connectors, and voltage on motor connectors (7‐12 VDC). |
22E |
Fan Motor (Fridge) |
Open fridge room duct and check if fan motor is jammed or stuck in ice. Reconnect and try again. Operate test mode to check if fan motor is working. Check wiring, connectors, and voltage on motor connectors (7‐12 VDC). |
24E |
Defrost Error (Freezer) |
Open freezer room and check heater continuity, thermal fuse continuity, bimetal, and wiring. |
29E |
Defrost Error (Cool Select Zone) |
Open cool select room and check heater continuity, thermal fuse continuity, bimetal, and wiring. |
31E |
Fan Motor (Cool Select Zone) |
Open cool select room duct and check if fan motor is jammed or stuck in ice. Reconnect and try again. Operate test mode to check if fan motor is working. Check wiring, connectors, and voltage on motor connectors (7‐12 VDC). |
39E |
Ice Maker Function (Fridge Room) |
Check ice maker kit for visible damage, stuck ice, lever operation, and press test switch below ice maker kit. Replace ice maker unit if error persists. |
40E |
Fan Motor (Ice Maker) |
Check if fan motor is jammed or stuck in ice. Check voltage (7‐12 VDC) on terminal during test mode. Check wiring for positive, negative, and feedback to PCB. |
41E |
Communication Error |
Check wiring between main PCB and display PCB. Replace main and display PCB if wiring is okay. |
44E |
Communication Error |
Main PCB and display PCB communication error. Check power supply in inverter PCB; replace both PCBs if required. |
61E |
Fridge Ice Duct Heater |
Check heater, thermal fuse, and bimetal continuity. Check wiring if the above components are okay. |
65E |
Fridge Ice Bucket Heater |
Check heater, thermal fuse, and bimetal continuity. Check wiring if the above components are okay. |
66E |
Door Handle Heater |
Check door handle heater continuity: 0≈ short, infinite ≈ open. |
71E |
Freezer Temperature Abnormally High |
Check if the door has been open for a long time. Check for gas charging defect. |
72E |
Fridge Temperature Abnormally High |
Check if the door has been open for a long time. Check for gas charging defect. |
81E |
Compressor Start Failure |
Check inverter PCB output supply; check for gas choke-up. |
82E |
IPM Failure |
Check inverter PCB for short circuit, and replace inverter PCB if necessary. |
83E |
Compressor Location Error |
Check compressor terminal open and compressor wiring. Open≈ No beep on multimeter. |
84E |
Compressor Locked Error |
Check compressor run without gas. Replace compressor if gas lines are clear. |
85E |
Low Voltage Error |
Check power supply for loose contact. Voltage should be 230 VAC or as per country standards. |
86E |
Over Voltage Error |
Check that the voltage of the power supply does not exceed country standards. |
87E |
R Comp Start Failure |
Check inverter PCB output supply; check for gas choke-up. |
88E |
R Comp IPM Fault |
Check inverter PCB for short circuit, and replace inverter PCB if necessary. |
89E |
R Comp Location |
Check compressor terminal open and compressor wiring. Open≈ No beep on multimeter. |
90E |
R Comp Locked Error |
Check compressor run without gas. Replace compressor if gas lines are clear. |
91E |
R Comp Low Voltage |
Check power supply for loose contact. Voltage should be 230 VAC or as per country standards. |
92E |
R Comp Over Voltage Error |
Check that the voltage of the power supply does not exceed country standards. |
Post Disclaimer
The content provided by MBMTech Services is for informational purposes only. While we strive to ensure the accuracy of the information and instructions, repairs and troubleshooting procedures can be complex and may vary depending on the specific product, model, or situation. Attempting to repair electronic devices or products yourself carries the risk of further damage, injury, or voiding warranties. MBMTech Services is not responsible for any damage, loss, or injury that may occur as a result of following the advice, instructions, or techniques presented in our videos or content. We strongly recommend consulting a professional technician for repairs or technical support. Use the information at your own risk.