Midea SBS Error Codes
Error Code | Description | Solution |
---|---|---|
E0 | Icemaker Sensor Error |
– Check the temperature sensor for damage. Replace if necessary. – Inspect the wiring for any loose or broken connections; repair if needed. – Check ohm on multimeter; value should be 1 (open) or 0 (short). |
E1 | Refrigerator Sensor Error |
– Check the temperature sensor for damage. Replace if necessary. – Inspect the wiring for any loose or broken connections; repair if needed. – Check ohm on multimeter; value should be 1 (open) or 0 (short). |
E2 | Freezer Duct Sensor Error |
– Check the temperature sensor for damage. Replace if necessary. – Inspect the wiring for any loose or broken connections; repair if needed. – Check ohm on multimeter; value should be 1 (open) or 0 (short). |
E3 | Variable Compartment Sensor Error |
– Check the temperature sensor for damage. Replace if necessary. – Inspect the wiring for any loose or broken connections; repair if needed. – Check ohm on multimeter; value should be 1 (open) or 0 (short). |
E4 | Refrigerator Defrost Sensor Error |
– Check the temperature sensor for damage. Replace if necessary. – Inspect the wiring for any loose or broken connections; repair if needed. – Check ohm on multimeter; value should be 1 (open) or 0 (short). |
E5 | Freezer Defrost Sensor Error |
– Check the temperature sensor for damage. Replace if necessary. – Inspect the wiring for any loose or broken connections; repair if needed. – Check ohm on multimeter; value should be 1 (open) or 0 (short). |
E6 | Communication Error | Check wiring between main PCB and display PCB. |
E7 | Ambient Sensor Error |
– Check the temperature sensor for damage. Replace if necessary. – Inspect the wiring for any loose or broken connections; repair if needed. – Check ohm on multimeter; value should be 1 (open) or 0 (short). |
E8 | Variable Compartment Defrost Sensor Error |
– Check the temperature sensor for damage. Replace if necessary. – Inspect the wiring for any loose or broken connections; repair if needed. – Check ohm on multimeter; value should be 1 (open) or 0 (short). |
E9 | Freezer No Cooling Alarm |
– Check if the compressor is running. – Inspect for gas leakage or blockage. |
EE | Icemaker Unit Error (including PCB) | Replace the icemaker and/or main PCB. |
EF | Water Tank Not Fitted Properly | Remove and refit the water tank, ensuring it is aligned with the slots correctly. |
CA | Communication Error between Main PCB and Icemaker PCB | Check wiring between the main PCB and the icemaker PCB. |