Error Code |
Description |
Solution |
E1 |
Indoor/outdoor unit communication error |
Check communication wiring between indoor and outdoor units. Reconnect or replace wires if needed. |
E2 |
Indoor unit coil temperature sensor error |
Inspect the coil temperature sensor in the indoor unit. Replace it if defective. |
E3 |
High pressure protection error |
Check refrigerant levels, clean the outdoor unit, and ensure proper ventilation. |
E4 |
Outdoor unit temperature sensor error |
Inspect the temperature sensor in the outdoor unit. Replace it if faulty. |
E5 |
Compressor overload protection |
Check for overheating in the compressor. Ensure the unit is properly ventilated and refrigerant levels are correct. |
P0 |
Inverter module protection |
Check the inverter module for faults. Reset or replace the module if needed. |
P1 |
Voltage protection (high or low voltage) |
Ensure the power supply is stable and within acceptable voltage range. Use a voltage stabilizer if necessary. |
P2 |
Compressor temperature sensor error |
Inspect the temperature sensor attached to the compressor. Replace it if faulty. |
P3 |
Outdoor ambient temperature sensor error |
Check the ambient temperature sensor outside the unit. Replace it if defective. |
P4 |
Compressor drive error |
Inspect the compressor drive components. Reset or replace as necessary. |
F0 |
Indoor fan speed error |
Check the indoor fan motor for faults. Repair or replace if needed. |