Error Code | Description | Solution |
---|---|---|
U0 | Low refrigerant in the system | Check for refrigerant leaks and recharge the system with the correct amount of refrigerant. |
U2 | Power supply problem | Ensure the power supply is stable; check for voltage fluctuations or power failures. |
U4 | Communication error between indoor and outdoor units | Inspect the communication wiring between the units; repair or replace if necessary. |
EA | Outdoor unit malfunction | Check the outdoor unit for issues such as fan malfunction or compressor failure. Repair or replace faulty components. |
J6 | Compressor overload | Check the compressor for overheating; inspect for any obstructions in airflow or excessive load on the compressor. |
L5 | Inverter drive error | Inspect the inverter drive and motor; reset or replace the inverter if it is faulty. |
P1 | High pressure in the system | Inspect for blockages in the refrigerant line and ensure proper ventilation for the outdoor unit. |
P4 | Overheating of the compressor | Check for proper ventilation and clean the air filters; reduce the compressor load if necessary. |
P9 | Outdoor air temperature sensor error | Inspect the outdoor temperature sensor; replace if it is malfunctioning. |
C9 | Indoor air temperature sensor error | Check the indoor temperature sensor; replace if necessary. |
Indoor unit faults
AC Error Codes and Solutions
Press and hold the “Cancel” button for 5 seconds until the display shows “00.” Then, continue pressing the “Cancel” button one time at a time. If the AC beeps twice at any point during this process, it means you’ve found the correct code, and the AC will stop functioning.
Error Code | Description | Solutions |
---|---|---|
00 | Normal operation | No action needed |
A0 | External protection | Check external connections and safety mechanisms |
A1 | PCB issue | Inspect or replace the printed circuit board |
A2 | Interlock fan problem | Verify the fan’s operation and interlock settings |
A3 | Drain abnormality | Check for blockages in the drain pipe |
A4 | Temperature abnormality at heat exchanger 1 | Inspect heat exchanger 1 for temperature issues |
A5 | Temperature abnormality at heat exchanger 2 | Inspect heat exchanger 2 for temperature issues |
A6 | Fan motor error | Check and possibly replace the fan motor |
A7 | Air swing motor error | Inspect the air swing motor and repair if needed |
A8 | AC input overcurrent | Check for electrical issues or overloading |
A9 | Expansion valve error | Examine the expansion valve for any malfunction |
AA | Abnormal heater temperature | Inspect the heater for temperature irregularities |
AH | Air cleaner defect | Clean or replace the air cleaner |
AC | Ignition process issue | Verify the ignition system |
AJ | Capacity determination device problem | Check the capacity determination system |
AE | Insufficient water | Check the water supply to the unit |
AF | Humidifier failure | Inspect the humidifier for faults |
C0 | Thermistor fault | Check and replace the thermistor if necessary |
C1 | Unspecified error | Consult the manual for further troubleshooting |
C2 | Unspecified error | Consult the manual for further troubleshooting |
C3 | Drain water level error | Ensure the drain water level is within acceptable limits |
C4 | Thermistor fault at heat exchanger 1 | Inspect or replace the thermistor at heat exchanger 1 |
C5 | Thermistor fault at heat exchanger 2 | Inspect or replace the thermistor at heat exchanger 2 |
C6 | Fan motor overload | Reduce load or replace the fan motor if needed |
C7 | Air swing motor locked | Unlock or repair the air swing motor |
C8 | AC input overcurrent | Check for electrical issues or overloading |
C9 | Suction line thermistor fault | Check the suction line thermistor and replace if faulty |
CA | Air sensor error | Inspect or replace the air sensor |
CB | Dirt sensor error | Clean or replace the dirt sensor |
CC | Humidity sensor error | Check and replace the humidity sensor if needed |
CJ | Remote sensor error | Inspect the remote sensor for any issues |
CE | Radiation sensor error | Check the radiation sensor for faults |
CF | High-pressure switch error | Verify the high-pressure switch operation |
Post Disclaimer
The content provided by MBMTech Services is for informational purposes only. While we strive to ensure the accuracy of the information and instructions, repairs and troubleshooting procedures can be complex and may vary depending on the specific product, model, or situation. Attempting to repair electronic devices or products yourself carries the risk of further damage, injury, or voiding warranties. MBMTech Services is not responsible for any damage, loss, or injury that may occur as a result of following the advice, instructions, or techniques presented in our videos or content. We strongly recommend consulting a professional technician for repairs or technical support. Use the information at your own risk.