TCL Airconditioner error codes

TCL Inverter AC Error Codes

TCL Inverter Air Conditioner Error Codes and Solutions

Error Code Description Solution
E1 High-pressure protection Check the condenser for blockages and ensure proper airflow. Inspect refrigerant levels.
E2 Indoor unit coil temperature sensor error Inspect the coil sensor and its connections. Replace if faulty.
E3 Low-pressure protection Check for refrigerant leaks, ensure proper pressure levels, and repair any leaks.
E4 Outdoor unit discharge temperature protection Check discharge temperature sensor and wiring for faults, ensure proper airflow in the outdoor unit.
E5 Overcurrent protection Check for power supply issues, and inspect the compressor and fan motors for damage.
E6 Communication error between indoor and outdoor units Verify the communication wiring and connections between indoor and outdoor units.
E7 Compressor overheat protection Let the compressor cool down, inspect for obstructions, and verify refrigerant levels.
E8 Indoor fan motor error Inspect the indoor fan motor and its wiring for faults or obstructions.
E9 Outdoor fan motor error Check the outdoor fan motor and wiring for issues. Ensure the fan is operating properly.
F0 Refrigerant leakage or low refrigerant Inspect for refrigerant leaks and refill if necessary. Check pressure sensors.
F1 Indoor ambient temperature sensor error Inspect the indoor temperature sensor for faults or loose connections.
F2 Outdoor ambient temperature sensor error Check the outdoor ambient sensor and its wiring for faults.
F3 Compressor discharge temperature sensor error Inspect the discharge sensor and its connections. Replace if needed.