O general Airconditioner error codes

O General Inverter Air Conditioner Error Codes
Error Code Description Solution
EA Indoor Unit Coil Sensor Error Inspect and replace the indoor unit coil sensor if faulty.
EE Indoor Unit Room Temperature Sensor Error Check and replace the room temperature sensor in the indoor unit if necessary.
EH Compressor Overload Protection Ensure that the compressor is not overheating. Check airflow and clean filters if blocked.
EL Outdoor Unit Temperature Sensor Error Inspect the outdoor unit temperature sensor and replace if needed.
EO Outdoor Unit Coil Sensor Error Check and replace the outdoor coil sensor if required.
EC Communication Error Between Indoor and Outdoor Units Check the wiring connections between the indoor and outdoor units. Fix any loose or damaged connections.
EU Fan Motor Error Inspect the fan motor for proper operation. Replace if malfunctioning.
F1 High Pressure Protection Check for blockages in refrigerant lines and clear obstructions if necessary.
F2 Low Pressure Protection Ensure proper refrigerant levels and inspect for any leaks. Recharge refrigerant if needed.
F3 Refrigerant Leakage Detection Check for refrigerant leaks and repair any found. Recharge the refrigerant if necessary.
F4 Overcurrent Protection Check the electrical supply for irregularities. Ensure no excessive current is being drawn.