Error Code Description Solution
E1 High pressure protection Check the refrigerant level, clean the outdoor unit, and ensure proper ventilation.
E2 Indoor temperature sensor malfunction Inspect the indoor temperature sensor and replace it if necessary.
E3 Low pressure protection Check for refrigerant leaks and ensure proper refrigerant levels.
E4 Compressor discharge temperature error Check for compressor overheating, ensure proper airflow, and inspect refrigerant levels.
E5 Communication error between indoor and outdoor units Inspect the communication wiring between the indoor and outdoor units and ensure proper connection.
F0 Indoor fan speed error Inspect the indoor fan motor; repair or replace if necessary.
F1 Outdoor temperature sensor error Inspect the outdoor temperature sensor; replace it if faulty.
P0 Inverter module protection Check the inverter module; reset or replace if needed.
P1 Voltage protection (high or low voltage) Ensure the power supply is stable and within the specified voltage range. Use a stabilizer if needed.
H3 Compressor overload protection Check the compressor for overheating and ensure proper refrigerant levels.
H6 Indoor fan motor malfunction Inspect the indoor fan motor; repair or replace if necessary.